November 2017
Page 12
3.2.4 Earth grounding
3.2.5 Mounting of NIO200
Mounting method in NIO200 is default with simple wall mounting kit. If the installation is
with pole mounting method, then user should purchase pole mounting kit for the
installation. Here is the guide for both simple wall mounting method and pole mounting
method:
A.Simple wall mounting method:
1.
Be sure to ground the 0.75mm
2
ground screw
with an appropriate grounding wire ( Earth,
Green/Yellow wire 18AWG, not included) by
attaching it to a good earth ground connection.
2.
There must be a disconnect device in front of
“NIO200 series” to keep the worker or field side
maintainer be cautious and aware to close the
general power supply before they start to do
maintenance.
3.
The disconnect device hereby means a 20A
circuit-breaker. Power installation must be
performed with qualified electrician and followed
with National Electrical Code, ANSI/NFPA 70 and
Canadian Electrical Code, Part I, CSA C22.1.