Copyright © 2018 NEXCOM International Co., Ltd. All Rights Reserved.
41
NSA 7145 User Manual
Chapter 4: BIOS Setup
Serial Port for Out-of-Band Management / Windows EMS
Advanced
Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2017 American Megatrends, Inc.
→←: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
VT-UTF8 is the preferred
terminal type for out-of-band
management. The next best
choice is VT100+ and then
VT100. See above, in Console
Redirection Settings
Out-of-Band Mgmt Port
Terminal Type
Bits per second
Flow Control
Data Bits
Parity
Stop Bits
COM0
[VT-UTF8]
[115200]
[None]
8
None
1
Terminal Type
ANSI
Extended ASCII character set.
VT100 ASCII character set.
VT100+ Extends VT100 to support color, function keys, etc.
VT-UTF8 Uses UTF8 encoding to map Unicode characters onto 1 or more
bytes.
Bits per second
Selects the serial port transmission speed. The speed must match the other
side. Long or noisy lines may require a lower speed.
Flow Control
Flow control can prevent data loss from buffer overflow. When sending data
and the receiving buffers are full, a “stop” signal can be sent to stop the
data flow.