GAS HOOK-UP
5. When connecting regulator assembly to
the valve, hand tighten the quick coupling
nut clockwise to a complete stop. Do not
use a wrench to tighten. Use of a wrench
may damage the quick coupling nut and
result in a hazardous condition.
6. Open the tank valve fully
(counterclockwise). Apply the soap
solution with a clean brush to all gas
connections. See below. If growing
bubbles appear in the solution the
connections are not properly sealed.
Check each fitting and tighten or repair as
necessary.
7. If you have a gas connection leak you
cannot repair, turn gas OFF at supply
tank, disconnect fuel line from your grill
and call 1-866-984-7455 or your gas
supplier for repair assistance.
8. Also apply soapy solution to the tank
seams. See below. If growing bubbles
appear, shut tank OFF and do not use
or move it! Contact an LP gas supplier
or your fire department for assistance
To disconnect L.P. gas cylinder:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn
clockwise to stop).
3. Detach the regulator assembly from the
tank valve by turning the quick coupling
nut counterclockwise.
INSTALLER FINAL CHECK LIST
PROPANE CYLINDER CAUTIONS
9
Specified clearance maintained
24”(61cm) from combustibles.
9
All internal packaging removed.
9
Knobs turn freely.
9
Burners are tight and sitting properly
on orifices.
9
Pressure regulator connected and set.
Gas connections to grill using hose &
regulator assembly provided (pre-set
for 11.0” water column).
9
Unit tested and free of leaks.
9
User informed of gas supply shut off
valve location
USER, PLEASE RETAIN THIS MANUAL
FOR FUTURE REFERENCE.
a) Do Not store a spare LP-gas
cylinder under or near this
appliance.
b) NEVER fill the cylinder beyond 80
percent full.
c) If the information in “a” and “b” is
not followed exactly, a fire causing
death or serious injury may occur.