SAFETY CHECKS
STEP 1:
1. Check connection from regulator to propane
tank connection. Remember, the connection is a
left-hand thread. (See diagram for Step 1)
2. Check all connections on the hose regulator
assembly (See diagram for Step 1)
3. Check intake hose for kink or in a position
that could cause it to kink. Hand tighten the
connection to the gas tank. (See diagram for
Step 1)
NOTE: The remaining connections are to be
tested after the heater has been lit.
2
1
Step 1.
STEP 2:
4. Light the heater following instructions on
page 10 and page 13-14.
5. Using spray bottle with soapy water, spray
each of the areas listed below to visually
inspect for leaks. Leaks will be indicated by
bubbles.
6. Intake hose fitting (#4) at bottom of safety
control valve. (See diagram for Step 2)
7. Pilot tubing (#5) to safety control valve.
(See diagram for Step 2)
8. Orifice fitting (#6) and the safety control
valve. (See diagram for Step 2)
9. Pilot tubing and pilot (#3). (See diagram for
Step 2)
NOTE:
After leak testing is completed and all
leaks are sealed, close the door to the tank
enclosure and your patio heater is ready to
use.
5
6
4
3
Step 2.