4 Configurations on Web Interface
Timeout for off-hook
Mainly used to define a timer that when the user is off hook an
analog phone without dial any digits
With the help of dialing timeout, you can limit the time between
two digits while users are typing the digits of a number through
Timeout for dialing
an extension. If the timeout expires, the gateway will consider the
dialing has finished and will try to send message to SIP server.
Default value is 4 seconds.
Timeout for
This parameter determines how long the caller party will wait for
answer(Outgoing
answer when making outgoing calls through a phone.
call)
Timeout for
This parameter determines how long the phone rings when there
answer(Incoming
are incoming calls
call)
No RTP Detected
If this parameter is enabled, the situation will be detected when
there is no RTP packets received during the set time period.
Period without RTP
The time period when there is no RTP packets received.
Packet
SUBSCRIBE for MWI
MWI is aimed to notify user that there is new voicemail. It is
(Message Waiting
Indicator)
realized in the way of NOTIFY.
MWI Subscription Expires
The expiry time of MWI subscription; Default value is 3600s.
Voicemail User ID
The user ID used to access to voicemail
Visual MWI Type
There are two visual MWI Type, namely NEON and FSK
Gateway-128s User Manual
42
Summary of Contents for FXS-128s
Page 1: ...FXS 128s Analog VoIP Gateway User Manual v1 0 1 ...
Page 15: ...2 Quick Installation l Connect network cable to the GE0 GE1 port Gateway 128s User Manual 10 ...
Page 36: ......
Page 38: ...4 Configurations on Web Interface Gateway 128s User Manual 32 ...
Page 42: ......
Page 47: ......
Page 59: ...4 Configurations on Web Interface 4 10 8 Feature Code Gateway 128s User Manual 51 ...
Page 60: ......
Page 73: ......
Page 80: ......
Page 83: ......
Page 94: ...4 Configurations on Web Interface Figure 4 63 Restart Device Gateway 128s User Manual 82 ...