CB-PTL Bulkhead Connector Assembly Installation
NexSens CB-Series buoy data wells capped with
pass through lids may optionally have UW
plug ports replaced with bulkhead cable connector assemblies.
Connector Types
The CB-PTL comes standard with a UW-6 power bulkhead cable assembly (
) pre-installed.
Wiring instructions for connection of this cable to user-supplied electronics are available
.
The RF bulkhead connector assembly (
) allows 3rd party modems to be integrated inside CB-
Series buoy data wells capped with
pass through lids or blank lids with user-drilled holes. It
consists of an N-style female connector integrated on the bulkhead for external antenna connection, and
1m pigtail cable with SMA male connector for connection to a modem placed inside the watertight data
well. Installation instructions for an RF-BULK cable assembly can be found
.
UW sensor bulkhead connector assemblies (
) allow for pluggable, watertight connection of
sensor cables to user-supplied electronics in the data well. Sensor cables must have a
for connection to the UW-BULK bulkhead receptacle. Installation instructions for a UW-
BULK cable assembly can be found
.
13
Summary of Contents for CB-450
Page 42: ...42 ...