background image

937-426-2703 

www.nexsens.com

2091 Exchange Court

Fairborn, Ohio 45324

Remove the white battery lid using the included 
3/16” hex driver and install the (16) D-cell alkaline 
batteries.

a.  Warning:

 

Ensure to follow the polarity labels 

located inside each battery tube. Polarity for 
all (4) batteries within each individual tube 
should be in the same orientation.

8

Figure 2: 

Remove the white battery lid.

Figure 3: 

Install the (16) D-cell alkaline batteries.

Reinstall the white battery lid.
a.  The device will beep once when the metal 

plate on the bottom of the lid makes contact 
with the batteries.

b.  Fully thread on the battery lid until it is flush 

with the top of the SDL tube. 

9

For additional information, please reference the X2-SDL Resource Library on the NexSens Knowledge Base.

nexsens.com/x2sdlkb

Wait up to 60 seconds for the system to check 
cellular coverage.
a.  Two consecutive beeps = adequate signal
b.  Three consecutive beeps = no signal

•  If three beeps are heard, move the X2-SDL 

into an area with strong cellular coverage.

•  Check cellular coverage through CONNECT 

using the link: 

nexsens.com/x2apn

10

After 20 minutes, refresh WQData LIVE and 
confirm all sensor parameters are shown and 
valid sensor readings appear.
a.  The device will beep for a duration of three 

seconds when detection is complete. 

11

Buzzer Event

When power is 

applied

Beep Type

During telemetry 

connection

Status

One short 

beep

Two short 

beeps

Three short 

beeps

System boot 

successful

Connection 

successfully 

established

No signal/connection 

failed

During telemetry 

connection

Buzzer Pattern Indicators

Table 1: 

X2-SDL Buzzer Pattern Indicators.

During sensor 

detection

Three second 

beep duration

WQData LIVE 

Setup 

Successfully

1

1

WQData LIVE setup is automatically done after sensor 

detection.

Reviews: