CB-PTL Bulkhead Connector Assembly Installation
NexSens CB-Series buoy data wells capped with
pass through lids may optionally have UW
plug ports replaced with bulkhead cable connector assemblies.
Connector Types
The CB-PTL comes standard with a UW-6 power bulkhead cable assembly (
) pre-installed.
Wiring instructions for connection of this cable to user-supplied electronics are available
.
The RF bulkhead connector assembly (
) allows 3rd party modems to be integrated inside
CB-Series buoy data wells capped with
pass through lids or blank lids with user-drilled holes.
It consists of an N-style female connector integrated on the bulkhead for external antenna connection,
and 1m pigtail cable with SMA male connector for connection to a modem placed inside the watertight
data well.
UW sensor bulkhead connector assemblies (
) allow for pluggable, watertight connection of
sensor cables to user-supplied electronics in the data well. Sensor cables must have a
for connection to the UW-BULK bulkhead receptacle.
Installation
Proper installation of bulkhead cable assemblies is essential in order to maintain the watertight integrity
of the data well. Installation of an RF-BULK cable assembly is shown below, but the procedure is the
same for UW6-BULK and UW-BULK cable assemblies.
1. Use a 1/8” Allen wrench, or equivalent tool, to loosen the nut from the threading on one of the
empty ports. Once loose, remove by hand and set aside.
Remove UW bulkhead plug.
13