Data Buoy Storage Requirements
The following practices should be carried out when storing a CB-Series buoy with an X2-CB data
logger for an extended period of time:
1. Store the buoy in a dry environment that is kept above freezing.
a. Cold or excessively fluctuating storage temperatures can weaken the PVC joints of the
deployment pipes.
2. Ensure the vent is clear of all obstructions.
a. If the vent is clogged, high pressure combustible gas can build up within the data well due to
outgassing from the batteries.
b. If planning to remove the plate from the data well, DO NOT use power tools.
3. Disconnect the 6-pin solar panel plug from the buoy’s SOLAR port as soon as the buoy is
removed from service.
a. The solar panel cable plug has an internal jumper that acts as a switch to supply on-board
electronics with power.
If the solar panel cable is left connected during storage, the batteries inside the
data well will die and require replacement.
4. Power OFF any LED beacons that are affixed to the buoy solar tower.
IR beacon remote can be used to accomplish this
according to the commands
Quick Start Guides.
b. If a remote is not available, remove the beacon and place it outdoors where it can receive
consistent sun to maintain charge.
5. Check the voltage of the SLA batteries in the buoy data well monthly and ensure they remain
above 12V. Follow the link below for proper guidance.
a.
Verify Battery Voltage of a CB-Series Buoy
M550
M650
45