31
3) Force setting - The unit is a percentage and set the lower limit of press force.
4) Standby position setting - In the recipe production, according to the highest point of the connector P1,
increase the distance to be the standby points, so that the press head to complete a single cycle operation,
standby for the next pressing position. This setting is to make a larger stroke machine not waste the time of
idle travel between the reciprocating OPR and the fixture. The set value is the surface that does not interfere
with the top side of the pressed object. The setting unit is mm.
2. System parameter setting -
1) Path setting - Set the data storage paths, which are the path settings of the related files such as the recipe
table file, the edited recipe file, the SPC statistical export data file, the pressed generated graph file, the
production record production data file, and the like.
2) Operating parameter - When the production is set, the pressing operation can be executed only when the bar
code or the serial number is forced to be scanned. However, when in sampling stage, there is no a serial number