NPS2400
User’s Manual
Rev. 3.0
– 17.02.2015
Page 32/38
6.6.8
DC/DC ConverterFailure error
Code, Type:
Time stamp:
Event:
Vout = 0V and Iout = 0A
. The internal DC/DC converter is not working properly. When such error occurs the device
goes in a latched shutdown mode. A mains power cycle is needed to recover from such error. Most of the cases this is an
unrecoverable error and the device needs to be serviced.
6.6.9
Short Circuit error
Code, Type:
Time stamp:
Event:
While in CONSTANT CURRENT mode the voltage drops below 1V for more then 0.5 seconds. The device enters a
hiccup cycle.
6.6.10
Over Load alarm start
Code, Type, Offending value:
Time stamp:
Event
:
Iout > IoutAlarm
(§6.4.6)
6.6.11
Over Load alarm end
Code, Type, Maximum value:
Time stamp:
Event
: Over Load condition alarm ends. Maximum value is the highest Iout measured during the alarm.
6.6.12
Over Temperature alarm start
Code, Type, Offending value:
Time stamp:
Event
:
Transformer temperature > 115 °C (239 °F)
6.6.13
Over Temperature alarm end
Code, Type, Maximum value:
Time stamp:
Event
: Over Temperature alarm condition ends. Maximum value is the highest temperature measured during the alarm.
6.6.14
Vin Under Voltage alarm start
Code, Type, Offending value:
Time stamp:
Event
:
Vin < VinMinAlarm
(§6.4.2).
OLS (AL) 100A
ddmmyy hh:mm:ss
IUVS(AL) 330V
ddmmyy hh:mm:ss
PSF (ER)
ddmmyy hh:mm:ss
OLE (AL) 130A
ddmmyy hh:mm:ss
SC (ER)
ddmmyy hh:mm:ss
OTS (AL) 115C
ddmmyy hh:mm
:ss
OTE (AL) 115C
ddmmyy hh:mm
:ss