NPSM121 Series Instruction Manual

NPSM121 Series V4.0

www.nextys.com

Page 4/5

Fig.1

Connections

Fig.2

Dimensions

Fig.3

Distances

Just for reference

(1)

AC/DC input

(2)

DC output (load)

(3)

Diagnostic Output

(dry contact, NC output OK)

(4)

Green LED: Output OK

(5)

Red LED: Overload

(6)

Output voltage adjustment

(7)

Selectable  limitation  mode

(Hiccup mode, C.C. mode)

Input AC Line:

L = Line

N = Neutral

I

= earth ground

Input DC Line:

L = + Positive DC

N = - Negative DC

I

= earth ground

Output:

+ = Positive DC

- = Negative DC

Dry contact = NC

Dimension

W

D

H

mm (inch)

35 (1.37)

104 (4.09)

103 (4.05)

Distance

A

B

mm (inch)

20 (0.8)

50 (2.0)

Fig.4

Mounting / Dismounting Instructions

For DIN rail fastening according to IEC 60715 TH35-7.5(-15)

Mounting as shown in figure, with input terminals on lower side, with suitable cooling and maintaining a proper distance between adjacent devices as specified in the I.S.

manual of each family.

Mounting:

1

2

1.

Tilt the unit slightly backwards.

2.

Fit the unit over the top edge of the rail.

3.

Slide it downward until it hits the stop.

4.

Press against the bottom for locking.

3

4

Summary of Contents for NPSM121 Series

Page 1: ...l efficiency Overload 150 Up to 60 C operating temperature with no derating Constant current or Hiccup mode limitation user settable Wide range of output voltage Easy parallelable for power increase Only 35mm width aluminum enclosure INDEX Page Installation Requirements 2 Declaration of Conformity 2 User Instructions 3 Connections 4 Dimensions 4 Distances 4 Mounting 4 Dismounting 5 Input Connectio...

Page 2: ...ispositivo prima di toccarlo Non far entrare liquidi o oggetti estranei nel dispositivo Per evitare scintille non collegare o scollegare l apparecchiatura prima di avere tolto tensione di ingresso e prima che sia avvenuta la scarica dei condensatori interni min 1 minuto RISQUE DE BRULURES EXPLOSION INCENDIE ELECTROCUTION DOMMAGE AUX PERSONNES Ne jamais effectuer des opérations sur les parties sous...

Page 3: ...upply to the load With output voltage set to the max value the continuous current x voltage must not exceed the nominal power 8 Parallel connection and redundancy power supplies can be connected in parallel to increase power For paralleling for power set the Ilim jumper to C C algorithm Uout must be set uniformly 100mV on each power supply and the wiring must be symmetrical to ensure an equal curr...

Page 4: ...gative DC I earth ground Output Positive DC Negative DC Dry contact NC Dimension W D H mm inch 35 1 37 104 4 09 103 4 05 Distance A B mm inch 20 0 8 50 2 0 Fig 4 Mounting Dismounting Instructions For DIN rail fastening according to IEC 60715 TH35 7 5 15 Mounting as shown in figure with input terminals on lower side with suitable cooling and maintaining a proper distance between adjacent devices as...

Page 5: ... SPD according to local regulations Fig 7 Input connections AC Line DC Line Fig 8 Environment Operating temperature Derating 35 C 70 C 5 95 r H non condensing UL Certified up to 60 C Overtemperature protection 1 2W C over 60 C Note Data may change without prior notice in order to improve the product Please refer to the latest version of the Instruction Manual for each product by visiting www nexty...

Reviews: