READ THIS CAREFULLY BEFORE INSTALLATION!

LEGGERE ATTENTAMENTE PRIMA

DELL’INSTALLAZIONE!

A LIRE ATTENTIVEMENT AVANT L’INSTALLATION!

Before operating, read this document thoroughly and retain

it for future reference.

Non-respect of these instructions may reduce

performances and safety of the devices and cause danger

for people and property.

The products must be installed, operated, serviced and

maintained by qualified personnel in compliance with

applicable standards and regulations.

Don’t open the device, it does not contain replaceable

components, the tripping of the internal fuse (if included) is

caused by an internal failure.

Don’t repair or modify the device, if malfunction or failure

should occur during operation, send unit to the factory for

inspection. No responsibility is assumed by Nextys SA for

any consequences deriving from the use of this material.

Prima dell’installazione, leggere attentamente questo

documento istruzioni e conservarle per future consultazioni.

L’inosservanza delle presenti istruzioni può compromettere le

caratteristiche e la sicurezza dell’apparecchio e causare

pericolo per le persone e le cose.

Il prodotto deve essere installato, utilizzato e riparato da

personale qualificato e nel rispetto delle normative vigenti.

Non aprire il prodotto, esso non contiene componenti sostituibili,

il guasto del fusibile interno (se previsto) è causato da un

guasto interno. Non tentare di riparare o modificare il prodotto,

se durante il funzionamento si verificano guasti o anomalie,

inviarlo al produttore per il controllo.

Nextys SA non si assume nessuna responsabilità per

qualunque conseguenza derivante dall’uso di questo materiale.

Lisez ces instructions avant l'installation, conservez ce

manuel pour référence future.

Défaut de se conformer à ces instructions peut affecter les

caractéristiques et la sécurité du dispositif de danger et de

causer aux personnes ou aux biens.

Les produits doivent être installés, exploité et entretenus par

personnel qualifié et en conformité avec les règlements.

N'ouvrez pas le produit, il ne contient aucune pièce réparable,

le déclenchement du fusible interne (le cas échéant) est

causé par un défaut interne. Ne pas essayer de réparer ou

modifier le produit ; si des défaillances se produisent pendant

le fonctionnement ou les dysfonctionnements, le retourner au

fabricant pour inspection. Nextys SA n'assume aucune

responsabilité des conséquences éventuelles découlant de

l'utilisation des produits.

CAUTION

ATTENZIONE

AVVERTISSEMENT

RISK OF BURNS, EXPLOSION, FIRE, ELECTRICAL

SHOCK, PERSONAL INJURY.

Never carry out work on live parts! Danger of fatal injury!

The product’s enclosure may be hot, allow time for cooling

product before touching it. Do not allow liquids or foreign

objects to enter into the products.

To avoid sparks, do not connect or disconnect the device

before having previously turned-off input power and wait for

internal capacitors discharge (minimum 1 minute).

RISCHIO USTIONI, ESPLOSIONE, INCENDIO, SCOSSA,

LESIONI GRAVI.

Non effettuare mai operazioni sulle parti sotto tensione! Pericolo

di lesioni letali! Il contenitore può scottare, lasciar quindi

raffreddare il dispositivo prima di toccarlo. Non far entrare liquidi

o oggetti estranei nel dispositivo.

Per evitare scintille, non collegare o scollegare

l'apparecchiatura prima di avere tolto tensione di ingresso e

prima che sia avvenuta la scarica dei condensatori interni (min.

1 minuto).

RISQUE DE BRULURES, EXPLOSION, INCENDIE,

ELECTROCUTION, DOMMAGE AUX PERSONNES.

Ne jamais effectuer des opérations sur les parties sous

tension! Danger de mort! Le récipient peut produire des

brulures, le laisser refroidir avant de toucher l'appareil. Ne

faites pas pénétrer des liquides ou des corps étrangers dans

l'appareil. Pour éviter des étincelles, ne pas connecter ou

déconnecter l'équipement jusqu'à ce que vous avez supprimé

la tension d'entrée et avant qu'elle n'ait lieu de décharge des

condensateurs internes (minimum 1 minute).

DECLARATION OF CONFORMITY

NEXTYS SA.

Via Luserte Sud 6, 6572 Quartino - Switzerland

Phone: +41-(0)91 840 14 46 / 840 14 48; Fax: +41-(0)91 840 14 47

E-mail: info@nextys.com

This Declaration of Conformity is suitable to the European Standard EN45014 "General criteria for supplier’s declaration of conformity".

We declare under our sole responsibility that the device included in this box, has passed all processing inspections and the final test and it is in conformity with the product

requirements, including all reference codes and supply specifications.

ROHS compliance:

 the product respects the EC requirements related to ROHS substances, according to “Restriction of Hazardous Substances” as per document 2011/65/UE

REACH compliance:

 the product respects the EC requirements related to REACH SVHC directive (2015)

Note:

 all the reported information comes from our suppliers, NEXTYS SA. has not run any test to evaluate if the specific elements are present.

All indicated devices are designed according to the latest Reference standards, if not expressly indicated through the official documents or files, they have been tested through

our internal pre-compliance testing. Consult directly on www.nextys.com the reference standards applied to each model.

Code

Description

NPST961-24

Three phases switching power supply IN 400 - 500Vac (520 - 725Vdc)/ OUT 24Vdc - 40A

NPST961-48

Three phases switching power supply IN 400 - 500Vac (520 - 725Vdc)/ OUT 48Vdc - 20A

NPST961-72

Three phases switching power supply IN 400 - 500Vac (520 - 725Vdc)/ OUT 72Vdc – 13.3A

Certifications and approvals

IND.CONT.EQ. 4WX9

Reference standards

2014/35/EU (2014)

(Low Voltage Directive)

2014/30/EU (2014)

(EMC directive)

EN60950-1:2006 /A2:2013

(Safety Standards)

UL508

(Certified - IND. CONT. EQ. 4WX9 file no. E356563)

EN61000-6-2:2005

(Generic immunity standard for industrial environments)

- EN61000-4-2:2008

(Electrostatic discharge immunity test)

- EN61000-4-3:2006 /A2:2010

(Radiated, radio-frequency, electromagnetic field immunity test)

- EN61000-4-4:2012

(Electrical fast transient/burst immunity test)

- EN61000-4-5:2014

(Surge immunity test)

- EN61000-4-11:2004 /A1:2010

(Voltage dips, short interruptions and voltage immunity test)

EN61000-6-3:2007 /A1:2011

(Generic emission standard for residential environments)

- EN55022:2010

(CISPR22 - EMC)

- EN55011:2009 /A1:2010

(CISPR11 - EMC)

Date:

25.02.2016

Place:

Quartino, Switzerland

The product manager

Marius Ciorica

Summary of Contents for NPST961 Series

Page 1: ...d 150 Up to 45 C operating temperature with no derating Constant current or Hiccup mode limitation user settable Easy parallelable for power increase Low noise thermally regulated 60mm fan INDEX Page Installation Requirements 2 Declaration of Conformity 2 User Instructions 3 Connections 4 Dimensions 4 Distances 4 Mounting 4 Dismounting 5 Input Connections 5 Environment 5 Accessory Device 5 ...

Page 2: ... operazioni sulle parti sotto tensione Pericolo di lesioni letali Il contenitore può scottare lasciar quindi raffreddare il dispositivo prima di toccarlo Non far entrare liquidi o oggetti estranei nel dispositivo Per evitare scintille non collegare o scollegare l apparecchiatura prima di avere tolto tensione di ingresso e prima che sia avvenuta la scarica dei condensatori interni min 1 minuto RISQ...

Page 3: ...wer supply to the load With output voltage set to the max value the continuous current x voltage must not exceed the nominal power 8 Parallel connection and redundancy power supplies can be connected in parallel to increase power For paralleling for power set the Ilim jumper to C C algorithm Uout must be set uniformly 100mV on each power supply and the wiring must be symmetrical to ensure an equal...

Page 4: ...ive DC L3 do not connect I earth ground Output Positive DC Negative DC Dry contact NC Dimension W D H mm inch 80 0 3 15 137 5 5 41 127 0 5 00 Distance A B mm inch 20 0 8 100 3 9 Fig 4 Mounting Dismounting Instructions For DIN rail fastening according to IEC 60715 TH35 7 5 15 Mounting as shown in figure with input terminals on lower side with suitable cooling and maintaining a proper distance betwe...

Page 5: ... type Surge protection it is strongly recommended to provide external surge arresters SPD according to local regulations Fig 7 Input connections AC Line DC Line Fig 8 Environment Operating temperature Derating 40 C 70 C 5 95 r H non condensing UL Certified up to 45 C Overtemperature protection 15 0W C over 45 C Note Data may change without prior notice in order to improve the product Please refer ...

Reviews: