background image

 

 
 

PSH150

 user manual rev4 

Page 1/15 

 

 
 
 
 
 
 
 

PSH150 

 

10kV Isolation Programmable Power 

Supply 

 

User Manual 

 
 
 
 

 

 
 
 
 

POWERMASTER

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PSH150

Page 1: ...PSH150 user manual rev4 Page 1 15 PSH150 10kV Isolation Programmable Power Supply User Manual POWERMASTER...

Page 2: ...ication in which the failure of the NEXTYS product could create a situation where personal injury or death may occur Should Buyer purchase or use NEXTYS products for any such unintended or unauthorize...

Page 3: ...atures and benefits 5 3 Functional description 6 3 1 Main DC output 7 3 2 Auxiliary 12V output 8 3 3 INHIBIT input 8 3 4 Display interface 8 3 4 1 Normal operation 8 3 4 2 Menu navigation 9 3 4 3 Alar...

Page 4: ...custom application Firmware update is also possible 4 INHIBIT input A voltage between 5Vdc and 30Vdc applied to this input activates the inhibit function 3 3 5 Auxiliary 12Vdc output This output provi...

Page 5: ...control and monitoring Multiple protections Can be paralleled for power or redundancy integrated ORing circuitry Up to 50 C operating temperature with no derating Wall mount fixing possible Suitable...

Page 6: ...y power supply of 12V 100mA is available An external INHIBIT signal can be applied for controlling the output status A multifunctional display shows the output parameters and 3 keys can be used for pr...

Page 7: ...derating curves are reported Current Derating Curve 0 2 4 6 8 10 12 14 40 30 20 10 0 10 20 30 40 50 60 70 80 Temperature C Current A 5V 12V 24V 48V Figure 3 PSH150 current derating curves Power Derati...

Page 8: ...ED display used to indicate the status and to navigate through the configuration menus During normal operation the output parameters are reported 3 4 1 Alarms and error codes are also reported on the...

Page 9: ...us addess 5s No store 2s Set Set Store Set 5s Output Voltage Modbus baudrate 5s No store 2s Set Set Store Set 5s Output Voltage Modbus stop bits 5s 2s Set Set Store Set 5s Output Voltage Modbus parity...

Page 10: ...al fault V A W USB power no mains available The product is powered through USB and the input mains is not present The user can navigate through the menus It can be used for firmware upgrade without th...

Page 11: ...put voltage Output current 0x2001 8193 Input register 3 4 Measured output current Output power 0x2002 8194 Input register 3 4 Measured output power Auxiliary voltage 0x2003 8195 Input register 3 4 Mea...

Page 12: ...rne Ne pas essayer de r parer ou modifier le produit si des d faillances se produisent pendant le fonctionnement ou les dysfonctionnements le retourner au fabricant pour inspection Nextys SA n assume...

Page 13: ...adjacent devices as specified in the I S manual of each family DIN rail mounting 1 Pull down to release and unlock the slide clamps 2 Tilt the unit slightly backwards 3 Fit the unit over the top edge...

Page 14: ...or 0 337 lbf Input output connections Solid 2 5mm 12AWG Stranded 1 5mm 12AWG L 6 0 7 5mm 0 24 0 30in Auxiliary connections Solid 0 5mm 20AWG Stranded 0 5mm 20AWG L 7 0 8 0mm 0 27 0 315in Input connect...

Page 15: ...designed according to the latest Reference standards if not expressly indicated through the official documents or files they have been tested through our internal pre compliance testing Consult direct...