nexusgroup.com // contact@nexusgroup.com
3
Installation Manual
Scoria Touch
2.0 Installation
2.1 Mounting
1. Identify a suitable location on a wall or at surface.
2. Stick the Drilling Template provided on chosen location. Drill 3 holes as indicated in the
diagram.
3. Insert 3 nos. of 6 mm wall plugs provided into the drilled holes.
4. Route the cables through the holes provided in the BackPlate.
5. Fix the BackPlate rmly on the wall using 3 nos. of 4 x 30mm CSK screws.
6. Connect wires to PCB.
7. After wiring, place the Housing over the xed BackPlate and guide the slot into the Back-
Plate tab and slide it downwards.
8. Fix the Housing to the Back-Plate with a M3 x 6 mm Security Screw on the bottom of the
Housing using a Security Screwdriver provided.
Important Note: Several layers of protection are provided against transient voltages from
static discharge, lightning and power supply spikes. For protection to be fully effective,
earthing should be done correctly.
3.0 Applications
Light switches
Exit button (Access control)
Elevator buttons
Industrial panels
3.1 PCB view
Important Note: Several layers of protection are provided
against transient voltages from static discharge (ESD), lightning
and power supply spikes. For protection to be fully effective,
earthing should be done correctly to avoid any damage.