Table 4-8 Different Output Voltage Settings Depending on Clip Depth Setting Method
Clip Depth Setting Method
Output Voltage Setting Method
Crest factor
Sets the RMS of the clipped waveform
Clip ratio
Sets the RMS of the sine wave before clipping
--------
Notes
----------------------------------------------------------------------------------------------------------------
When the clipped sine wave is output in the AC mode, the clip of the output waveform may be
tilted by the DC component remove function in the AC mode. To avoid this, switch to the
ACDC mode.
---------------------------------------------------------------------------------------------------------------------------------
Operation procedure
1.
In the [Wave] item, select [CLP].
2.
Move the cursor to [Select], then select it. The clipped sine wave setting window opens.