4. Advanced Operation
PROGRAMMABLE AC POWER SOURCE
166
Turning off the Autocal function
1.
Open the Autocal set window. Following two methods are available.
(a)
Shortcut operation:
+
The window is toggled between the AGC setting window and the Autocal setting window
every time you press the keys.
(b)
Push the [Misc] soft-key and select [1: AGC/Auto Cal].
2.
In the [Auto Cal] item, select [1: OFF]. When [OFF] is selected here, the Autocal calibration
finishes, and the calibration factor is cleared.