4.28 Restoring to the Factory Default Setting (Reset)
DP Series
195
Table 4-14 Setting Items to be Reset (Continued)
Setting Item
Reset
Factory default setting
Sequence parameters
×
Output range: 100 V
AC/DC mode: AC-INT
Step Time: 0.1000 second
Intra-Step behavior: Constant
Waveform: SIN Frequency: 50 Hz
DC voltage: 0 V
AC phase voltage: 0 V
Start phase: Disabled, 0 deg
Stop phase: Disabled, 0 deg
Phase angle: Single-phase three-wire 180 deg
Three-phase 120, 240 deg
Step termination: Continue
Jump count: 1
Jump-to step specification: OFF
Step sync output: LL
Branch step specification: OFF
Trigger output: Off
Simulation parameters
×
Output range: 100 V
Step Time: 0.1 second
Frequency: 50 Hz AC voltage: 0 V
Start phase: Disabled, 0 deg
Stop phase: Disabled, 0 deg
Step sync output: LL
Trigger output: Off
Repeat count: Disabled 1
Operation procedure
1.
Press the MENU key to move to the root menu, then select [System]. The system setting
window opens.