6. Remote Control
PROGRAMMABLE AC POWER SOURCE
210
5.
Use a commercially available USB cable (Type A to B) to connect this product to the computer.
USB connector is available on the rear of this product.
--------
Notes
----------------------------------------------------------------------------------------------------------------
Avoid use in a place that has power fluctuation or under electrically noisy environment.
It is recommended to use a fully-shielded, short cable.
The use of USB hub may cause the product not to communicate properly.
---------------------------------------------------------------------------------------------------------------------------------
About USB ID
Used for a system connected with multiple DP Series programmable AC power sources through
USB, to enable the application identify each source. The USB ID is represented in the following
format.
USB0::[Vendor number]::[Product number]::[Serial number]::INSTR
Vendor number: Fixed to 3402 (0x0D4A)
Product number: Fixed to 26 (0x001A)
Serial number:
A unique number (serial number) has been set for each product.
6.1.2 RS232
For the interface specifications, see
.
Operation procedure
1.
Press the MENU key to move to the root menu, then select [System]. The system setting
window opens.