8.1 Error Messages and Error Handling
DP Series
223
8.1.3 If An Error Occurs Repeatedly
If an error message repeatedly appears even though you removed the cause of the error, the error
may be resolved by restarting the power unit.
If the error still exists, the product or the power unit in the product may be faulty. Repair is needed
in this case. Contact the seller (NF Corporation or our agent) from whom you purchased the product.
Even though one of the power units is faulty, the product can be used by disconnecting the faulty
power unit and using the rest of them.
The following shows how to restart and disconnect the power unit in the case of an error.
--------
Notes
----------------------------------------------------------------------------------------------------------------
The following procedure is available only when the [PU-ON] soft-key is displayed on the error
message window. Stop using the product in the case of a repeating error without the [PU-ON]
soft-key.
---------------------------------------------------------------------------------------------------------------------------------
Operation procedure
1.
In the error message window, press the [PU-ON] soft-key. The power unit energization setting
window opens.
2.
The power unit with an error is marked with "E" like
. Check on the power unit that has an
error. First, leaving the energization setting as is, select OK. All the power units are restarted.
3.
When the error message window is displayed again, press the ENTER key.
4.
If the error still exists, press the [PU-ON] soft-key again to open the power unit energization
setting window.
5.
Check on the power unit that has an error. If the same power unit still has an error, it may be
faulty. Move the cursor to this power unit, then press the ENTER key. The check mark on this
power unit is removed, showing
. If a different power unit has an error, leave the check
mark as is. Select [OK].
6.
The power unit energization setting is updated, and only the power units with the check mark
are restarted. When the error message window is displayed again, press the ENTER key.
7.
Repeat the step 4 and later ones until errors are resolved. After the error is resolved, the product
can be continuously used using the power units with the check mark.
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......