10.11 Measurement Function
DP Series
253
Load power factor (optional), Load crest factor (optional)
All
models
Measurement
range
0.00 to 1.00
Power
factor
Resolution
0.01
Measurement
range
0.00 to 50.00
Crest
factor
Resolution 0.01
Note: The power factor is not displayed in the DC mode.
Synchronization frequency (only SYNC)
All
models
Display range
38.0 Hz to 525.0 Hz
Resolution 0.1
Hz
Accuracy
±
0.2 Hz
Harmonic current (optional, AC - INT, fundamental wave 50 Hz/60 Hz only, phase current)
Single-phase model, Polyphase model, Multi-phase model
015S,030D,045T
045M (polyphase
output)
030S,060D,090T
090M (polyphase
output)
045S
045M
(single-phase
output)
090D
Measurement
range
Up to 40th order of the fundamental wave
Full scale
20 A / 10A
100%
40 A / 20A
100%
60 A / 30A
100%
Resolution 0.01
A
0.1%
Up to 20th
±
(1% of rdg
+ 0.2 A / 0.2 A)
±
(1% of rdg
+ 0.4 A / 0.2 A)
±
(1% of rdg
+ 0.6 A / 0.3 A)
±
(1% of rdg
+ 0.8 A / 0.4 A)
20th to 40th
Effective
value
(rms)
Percent
(%)
Accuracy
(At RMS,
reference
value)
±
(1.5% of rdg
+ 0.2 A / 0.2 A)
±
(1.5% of rdg
+ 0.4 A / 0.2 A)
±
(1.5% of rdg
+ 0.6 A / 0.3 A)
±
(1.5% of rdg
+ 0.8 A / 0.4 A)
Single-phase model, Single-phase three-wire model, Single-phase output of the
Multi-phase model
060S, 120D
075S
090S, 090M
105S
120S
Measurement
range
Up to 40th order of the fundamental wave
Full scale
80 A / 40A
100%
100 A / 50A
100%
120 A / 60A
100%
140 A / 70A
100%
160 A / 80A
100%
Resolution 0.01
A
0.1%
Up to 20th
±
(1% of rdg
+ 0.8 A / 0.4 A)
±
(1% of rdg + 1.2 A / 0.6 A)
±
(1% of rdg + 1.6 A / 0.8 A)
20th to 40th
Effective
value
(rms)
Percent
(%)
Accuracy
(At RMS,
reference
value)
±
(1.5% of rdg
+ 0.8 A / 0.4 A)
±
(1.5% of rdg + 1.2 A / 0.6 A)
±
(1.5% of rdg + 1.6 A / 0.8 A)
Note: The measurement does not conform to the IEC or other standard.
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......