10. Specifications
PROGRAMMABLE AC POWER SOURCE
254
Display of emission CO
2
All
models
Displayed items
Displays the instantaneous (kgCO
2
/h) and integration (tCO
2
, can be cleared)
values for the internal loss and the output power
Full scale
Instantaneous: 20 kgCO
2
/h, Integration: 2000 tCO
2
Resolution
Instantaneous: 0.001 kgCO
2
/h, Integration: 0.000001 tCO
2
Emission CO
2
coefficient
Variable (resolution 0.000001 tCO
2
/kWh)
Factory default: 0.000555 tCO
2
/kWh
10.12 Power Unit Energization Setting
The power consumption can be decreased by decreasing the number of the power units in operation
according to the load capacity. Each power unit can be enabled (energized)/disabled (not energized)
separately. (1.5 kVA or 1.5 kW/power unit)
Single-phase model and Single-phase output of Multi-phase model
015S 030S
045S
045M
060S 075S
090S
090M
105S 120S
Number
of
units
1 2 3 4 5 6 7 8
Energizing
setting
No Yes
Note: Can be set for only a model with more than one unit.
Polyphase model and Polyphase output of Multi-phase model
030D 060D 090D 120D
045T
045M
090T
090M
Number of units
(per phase)
1 2 3 4 1 2
Energizing
setting
No Yes No
Yes
Note: Can be set for only a model with more than one unit per phase.
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......