10.13 Current Limiter
DP Series
255
10.13 Current Limiter
This controls the output voltage for the output current to be within the limiter setting value when the
peak value or RMS exceeds it. The output can be configured to be turned off when the limited state
continues over the specified time.
In the polyphase model, polyphase system, and polyphase output of the Multi-phase model, the
settings are made for the phase current and common to all the phases.
Peak current limiter
Single-phase model, Polyphase model, Multi-phase model
015S,030D,045T
045M (polyphase
output)
030S,060D,090T
090M (polyphase
output)
045S, 090D
060S, 120D
Setting
Range
(Peak
value)
+7.5 A
to
+63.0 A /
+3.7 A
to
+31.5 A
+15.0 A
to
+126.0 A /
+7.5 A
to
+63.0 A
+22.5 A
to
+189.0 A /
+11.2 A
to
+94.5 A
+30.0 A
to
+252.0 A /
+15.0 A
to
+126.0 A
Positive
current
Factory
default
+63.0 A / +31.5 A
+126.0 A /
+63.0 A
+189.0 A /
+94.5 A
+252.0 A /
+126.0 A
Setting
Range
(Peak
value)
−
63.0 A
to
−
7.5 A /
−
31.5 A
to
−
3.7 A
−
126.0 A
to
−
15.0 A /
−
63.0 A
to
−
7.5 A
−
189.0 A
to
−
22.5 A /
−
94.5 A
to
−
11.2 A
−
252.0 A
to
−
30.0 A /
−
126.0 A
to
−
15.0 A
Negative
current
Factory
default
−
63.0 A /
−
31.5 A
−
126.0 A /
−
63.0 A
−
189.0 A /
−
94.5 A
−
252.0 A /
−
126.0 A
Resolution 0.1
A
Limiter operation
Select whether to recover automatically (continuous, factory default) or
turn the output off when the limited state continues over the specified time
(1 s to 10 s, resolution 1 s).
Single-phase model and Single-phase output of Multi-phase model
075S 090S,
090M 105S 120S
Setting
Range
(Peak
value)
+37.5 A
to
+315.0 A /
+18.7 A
to
+157.5 A
+45.0 A
to
+378.0 A /
+22.5 A
to
+189.0 A
+52.5 A
to
+441.0 A /
+26.2 A
to
+220.5 A
+60.0 A
to
+504.0 A /
+30.0 A
to
+252.0 A
Positive
current
Factory
default
+315.0 A /
+157.5 A
+378.0 A /
+189.0 A
+441.0 A /
+220.5 A
+504.0 A /
+252.0 A
Setting
Range
(Peak
value)
−
315.0 A
to
−
37.5 A
/
−
157.5 A
to
−
18.7 A
−
378.0 A
to
−
45.0 A /
−
189.0 A
to
−
22.5 A
−
441.0 A
to
−
52.5 A /
−
220.5 A
to
−
26.2 A
−
504.0 A
to
−
60.0 A /
−
252.0 A
to
−
30.0 A
Negative
current
Factory
default
−
315.0 A /
−
157.5 A
−
378.0 A /
−
189.0 A
−
441.0 A /
−
220.5 A
−
504.0 A /
−
252.0 A
Resolution 0.1
A
Limiter operation
Select whether to recover automatically (continuous, factory default) or
turn the output off when the limited state continues over the specified time
(1 s to 10 s, resolution 1 s).
Note: If you increased or decreased the number of units by the power unit energization setting, the
factory default setting corresponding to the capacity is used. (Example: In the case that only
3 units operate in 6 kVA model, the factory default setting of 4.5 kVA model is used.)
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......