3. Basic Operation
PROGRAMMABLE AC POWER SOURCE
56
--------
Notes
----------------------------------------------------------------------------------------------------------------
The line voltage can be set only for the sine wave in the balanced mode.
---------------------------------------------------------------------------------------------------------------------------------
3.4.6 Setting the Output Frequency
Set the AC component frequency of the internal signal source.
Operation procedure
1.
Select the [Freq] item and follow the instructions in
to enter a value.
3.4.7 Setting the Output On/Off Phase
Set the phases when the output turns on/off. After the output-on operation, the voltage output is
started from the output on phase. After the output off operation, the voltage output is completed
when it reaches the output off phase. The output off phase can be disabled. If disabled, the output is
turned off immediately after the operation of output off.
Operation procedure
1.
Press the [Osc] soft-key and select [4:On/Off Phs]. The output on/off phase setting window
opens.