4.1 Using Limiter, Setting Limiter
DP Series
71
2.
Set the value of RMS current limiter in [Io] item.
3.
Set the [Output OFF] item as [Enable] or [Disable]. When setting to [Enable], also set the time
from the start of limiter operation to the output off.
4.
Close the window.
4.1.3 Using Voltage Setting Range Limit
For the continuous output function, when the signal source is INT, SYNC, or ADD, the range of the
output voltage setting value to the internal signal source can be limited. Even if trying to set a
voltage that exceeds the limit, the setting value is restricted to the limiting value. This can prevent
mis-setting when you do not want to set values outside the range.
As for the voltage setting range limiting values, each value is kept independently for the following
settings for 100 V and 200 V ranges respectively: SIN/CLP waveform in AC mode, ARB waveform
in AC mode, ACDC mode, and DC mode.
In case of polyphase output, the setting of the voltage setting range limit is common to all phases,
and kept as the effective value of the phase voltage in this product. When the line voltage setting
(effective value setting) is selected in balanced mode, it is converted into the effective value setting
of the phase voltage according to the following formula and kept in this product.
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......