5. Description of Screen and Menu
PROGRAMMABLE AC POWER SOURCE
200
5.1.2 Measured Value Display Items
The items displayed inthe measured value area are shown in Table 5-3.
Table 5-3 Measured Value Display Items
Item Description
Icon
Represents the phase and type of the measured voltage display.
Output voltage of the single-phase two-wire
Phase voltage of the single-phase three-wire L1 phase
Phase voltage of the single-phase three-wire L2 phase
Line voltage between the single-phase three-wire L1 and L2 phases.
*1
Phase voltage of the three-phase L1 phase
Phase voltage of the three-phase L2 phase
Phase voltage of the three-phase L3 phase
Line voltage between the three-phase L1 and L2 phases
*1
Line voltage between the three-phase L2 and L3 phases
*1
Line voltage between the three-phase L3 and L1 phases
*1
V
Effective value of the output voltage on the output terminal
Vavg
The average DC value of the output voltage on the output terminal
Vmax
Maximum peak value of the output voltage on the output terminal
Vmin
Minimum peak value of the output voltage on the output terminal
SV
Effective value of the voltage on the sensing terminal
SVavg
Average DC value of the voltage on the sensing terminal
SVmax
Maximum peak value of the voltage on the sensing terminal
SVmin
Minimum peak value of the voltage on the sensing terminal
I
*2
Output current effective value
Iavg
*4
Average DC value of the output current
Imax
*2
Maximum peak value of the output current
Imin
*2
Minimum peak value of the output current
Ipk-Hold
*2
Output current peak-hold value
F
Synchronization signal source frequency
P
*3
Output active power
S
*3
Output apparent power
Q
*3
Output reactive power
PF
*4
Power factor of the output power
CF
*4
Output current crest factor
*1: Displays the measured phase voltage value in the Peak display format of the measured value.
Displays the L1 phase voltage in the L1-L2 line voltage display, the L2 phase voltage in the
L2-L3 line voltage display, and the L3 phase voltage in the L3-L1 line voltage display.
*2: Displays the phase current in the phase voltage display for the measured output voltage,the
L1 phase current in the L1-L2 line voltage display, the L2 phase current in the L2-L3 line
voltage display, and the L3 phase current in the L3-L1 line voltage display.
*3:
Displays the phase output power in the phase voltage display for the output voltage
measurement, and the all-phase total output power in the line voltage display.
*4: Displays the phase measured value in the phase voltage display for the measured output
voltage. Displays nothing in the line voltage display.
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......