3. Basic Operation
PROGRAMMABLE AC POWER SOURCE
50
2.
+
Switching the signal source
Press the SHIFT key to enter the shift state (the SHIFT LED illuminates). When you press the 8
key of the numeric keypad during the shift state, the signal source is switched in the following
order: INT, VCA, SYNC, EXT, ADD, INT. Some signal sources may be skipped and cannot be
selected depending on the AC/DC mode.
3.4.2 Setting the Output Range
You can select the 100 V range or 200 V range. Table 3-10 shows the setting range for each range.
--------
Notes
----------------------------------------------------------------------------------------------------------------
You cannot switch the output range in the output on state.
---------------------------------------------------------------------------------------------------------------------------------
Table 3-10 The Setting Range per Output Range
Setting Range
Setting Item
100 V range
200 V range
Unit
DC voltage
−
220.0 to +220.0
−
440.0 to +440.0
V
SIN, CLP
0.0 to 155.0
0.0 to 310.0
Vrms
Phase Voltage
ARB
0.0 to 440.0
0.0 to 880.0
Vp-p
1P3W
SIN
0.0 to 310.0
0.0 to 620.0
Vrms
AC
vol
ta
ge
Line
voltage
3P4W
SIN
0.0 to 268.4
0.0 to 536.8
Vrms
External Input Gain
0.0 to 220.0
0.0 to 440.0
Times
Peak current limiter (positive)
Peak current limiter (negative)
RMS current limiter
Refer to
Voltage Setting Limit
Refer to
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......