3.4 Using the Continuous Function
DP Series
61
3.4.11 Enlarge Display Letters for the Measured Value
You can switch the measured value display mode between normal (normal) and the mode in which the
letters are enlarged (simple) shown in Figure 3–14. In the Simple View mode, three types of measured
values are displayed. You can select the measured value being displayed in the Simple View mode.
Figure 3-14 The Normal View (left) and the Simple View Mode (right)
--------
Notes
----------------------------------------------------------------------------------------------------------------
If the measured value display mode is changed to Peak in the Simple View mode, the
maximum peak values (Vmax/Imax) are displayed instead of the voltage/current measured
value. Also, if the measured value display mode is changed to RMS/AVG from Peak, the
effective/average values are displayed instead of the maximum and minimum peak values.
If the AC/DC mode and the signal source are changed in the Simple View mode, the measured
voltage values are forced to be displayed instead of the items that are not displayed in the mode after
the change, such as the power factor or crest factor. If this operation is applied to multiple items, the
measured current value is displayed for the second item, and the current peak-hold value for the third.
---------------------------------------------------------------------------------------------------------------------------------
Switching the measured value display mode (normal/simple)
The mode is toggled between normal and simple every time you perform the Shortcut operation with
+
. You can also change the mode by following the steps below.
1.
Press the [Measure] soft-key and select [1:Mode].
2.
Select 1: Normal/2: Simple.
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......