4.
Advanced Operation
PROGRAMMABLE AC POWER SOURCE
102
2.
When pushing [Compile] soft key in the Sequence Edit View, moved to Sequence Control View.
You can check measurements in step No.0. When pushing [Start] soft-key, the sequence is started.
3.
Remote Sensing function and Autocal function can be enabled in step No.0 in the Sequence Edit
View and the Sequence Control View.
■
Turning on the Remote Sensing Function
1.
Open the AGC/Autocal set window by shortcut operation:
+
.
2.
Use the [Rmt Sense] item to set the Remote sensing function to on or off.
3.
Close the window.
Sequence Edit View Sequence Control View
■
Turning on the Autocal Function
1.
Turn on the output.
2.
Open the AGC/Autocal set window by shortcut operation:
+
.
3.
Use the [Rmt Sense] item to set the Remote sensing function to on or off if necessary.
4.
Use the [Auto Cal] item to turn on the Autocal function. In case within operating range of Autocal
when [ON] is selected here, the calibration factor of the Autocal function is calculated, and the
calibration is started.
5.
Close the window.