4.20 Amplifying the External Signal Input
DP060LM/DP120LM/DP180LM
185
4.20 Amplifying
the
External Signal Input
When you select EXT for the signal source, you can output the amplified external signal. Also, when
you select ADD for the signal source, you can output the amplified external signal after the internal
signal is added. For the specifications of the gain setting range and the input voltage range, see
11.23.3
.
--------
Notes
------------------------------------------------------------------------------------------------------------
The gain setting value is retained for each of 100 V/200 V ranges.
Within the same range, the same value is retained for the gain setting value, regardless of the
combination of the AC/DC mode and the signal sources (VCA, EXT, ADD).
If the voltage after the external signal is amplified, or if the total voltage of the amplified
external signal and the internal signal exceeds
227 V (100 V range)/
454 V (200 V range),
the output voltage is clipped at that value.
If the signal source is set to EXT, the calculation is carried out in certain intervals by the
measurement function of this product. Therefore, the measurement operation cycle may
become inappropriate depending on the external signal frequency, resulting in the instable
measured value display. In that case, set [ADD] for the signal source and configure the settings
as below. When the signal source is set to [ADD], the measurement calculation is performed in
optimum interval for the frequency which is set for the internal signal source. This may solve
the instability of the measured value display.
Set the frequency for the internal signal source so that it is equal to the one for the external signal.
Set zero for ACV and DCV.
You cannot amplify the external signal in the polyphase model or polyphase system. Also, you
cannot select EXT or ADD for the signal source.
-----------------------------------------------------------------------------------------------------------------------------
Operation procedure
1.
Input the signal to be amplified from the external signal input connector.
2.
Press the [Osc] soft-key and select [2: Source], then : select [4:EXT] or [5:ADD].
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...