4.23 Power Unit Energization Setting (Using Under the Restricted Rated Power)
DP060LM/DP120LM/DP180LM
189
2.
In the [PwON Output] item, select [2:ON] or [1:OFF]. When you select [ON], the automatic
output-on at power-on is enabled.
4.23 Power Unit Energization Setting (Using Under the Restricted
Rated Power)
You can enable or disable the energization for each power unit (2 kVA per unit in DP060LM /
DP120LM, 6 kVA per unit in DP180LM) within this product. If the smaller power is needed for
handling the load, you can disable the energization for some power units to reduce the power
consumption of this product.
If there is a power unit on which the energization is disabled, the rated power icon is displayed
inverted. For details on the rated power icon, see
3.2.6
and
5.1.1
You can disable the energization for the power unit that may have a failure while continuing
operation of this product by using the remaining power units. For details, see
9.1.3
.
Operation procedure
1.
Press the MENU key to move to the root menu, then select [System]. The system setting window
opens.