11.27 External Control Function
DP060LM/DP120LM/DP180LM
273
11.27.1 CONTROL I/O
When you enabled the external control from the menu,
You can control this product by using the external signal (or non voltage contact). The state output is
always on. The detection and state switching is done at 10 ms-cycle.
If the Remote state is achieved by the external interface, a control input is ignored.
It is not available to use
11.27.2
at the same time.
Item Description
Factory
default
Control
input
External control input
Enabled or Disabled
Input level
TTL *63
Nondestructive maximum input
+10 V /
5 V
Input impedance
Pull-up to +5 V via 47 k
Control
Output Off
Falling Off
Output On
Falling On
Sequence start/resume
*64 Falling Start
Stop of sequence
*64 Falling Stop
Sequence is in the Hold status
Falling Hold
Sequence branch 1
Falling Branch start
Sequence branch 2
Falling Branch start
Memory recall (+ compile)
*65 Falling Recall
Memory specification 1
Specify 0 to 3
(Equivalent to memory 1 to 4,
respectively)
Memory specification 2
Clear the current peak-hold value
Falling Clear
State
output
Output level
TTL *66
Output impedance
220
Polarity
*67 Positive or negative
negative
Status
Power On/Off
Low: Off, High: On
Output On/Off*
Low: On, High: Off (Negative)
Low: Off, High: On (Positive)
Protection operation*
Low: Active, High: None (Negative)
Low: None, High: Active (Positive)
Limiter operation*
Low: Active, High: None (Negative)
Low: None, High: Active (Positive)
AGC/Autocal setting state*
Low: On, High: Off (Negative)
Low: Off, High: On (Positive)
Software busy*
Low: Busy, High: Ready (Negative)
Low: Ready, High: Busy (Positive)
Output range
Low: 200 V, High: 100 V
Sequence operation
Step sync 1
*64
High level or Low level
Sequence operation
Step sync 2
*64
Trigger positive
or negative
Terminal
D-sub 25-pin multi-connector (rear panel, female, M2.6 screw)
*63
:
Low: 0.8 V or lower, High: 2.6 V or higher, the chassis potential,
*64
:
Sequence start and stop of the control input are effective for the Simulation as well. Also, step sync
output 1 and 2 of the control output are effective for the Simulation as well.
*65
:
The memory recall input of the control input recalls the setting memory for the Normal
(Continuous), the Sequence Memory for the Sequence, and the Simulation Memory for the
Simulation. For the Sequence and Simulation, the compile data is also included.
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...