4.
Advanced Operation
PROGRAMMABLE AC POWER SOURCE
76
--------
Notes
------------------------------------------------------------------------------------------------------------
Step Start Phase setting can be disabled. In that case, the phase when the phase starts becomes
the phase when the previous step ended.
In DC mode, the step Start Phase cannot be set.
-----------------------------------------------------------------------------------------------------------------------------
Stop Phase (Stop Phs)
Determines the phase of AC waveform when the step ends. The phase when a step ends in L2 and L3
phase of polyphase output is the addition of the setting value of intra-Step parameter Phase and the
setting value of the step Stop Phase. When the stop phase setting is active, the execution waits for the
Step Time that was set pass, and keeps the output setting until it reaches the Stop Phase that was set,
and then transitions to the next step. As the result, the actual step time is longer by one cycle at a
maximum than the set Step Time. Figure 4-3 shows an example where both the Stop Phase of the
previous step and the Start Phase of the next step are set to 0°.
Figure 4-3 Stop Phase
--------
Notes
------------------------------------------------------------------------------------------------------------
When the Step Behavior is set to [Sweep], output is constant while waiting for the step Stop
Phase after the Step Time passes.
Step Stop Phase setting can be disabled. In this case, when the set Step Time has passed, the
execution transitions to the next step without waiting for step Stop Phase.
In DC mode, the step Stop Phase cannot be set.
-----------------------------------------------------------------------------------------------------------------------------
Trigger output (Trig Out)
State output to CONTROL I/O connector. This specifies whether the trigger output presents when the
step starts. Polarity and pulse width of the trigger output complies with the trigger output setting (see
4.2.5
).
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...