4.24 Power Unit Energization Setting (Using Under the Restricted Rated Power)
KP3000S
185
3.
Enable/Disable the energization. The power unit on which the energization is enabled/disabled
is represented by
/
respectively. Move the cursor to
/
and press the ENTER key to
switch between
and
.
4.
Select [OK]. The energization is enabled or disabled and the window is closed.
--------
Notes
------------------------------------------------------------------------------------------------------------
The maximum current, current monitor gain, current measurement full scale, and the power
measurement full scale are set to the values corresponding to the rated output power which is
determined by the number of power units to be energized. However, the applied current
measurement accuracy and the power measurement accuracy are the values under the
condition where all power units are enabled for energization.
If the number of the energized power units is changed, the setting values of the peak current
limiter and the RMS current limiter are restored to the factory default settings corresponding to
the rated power which is determined by the number of the power units to be energized.
If you select [OK] without changing the energization settings in the power unit energization
setting window, the energization settings of all power units are disabled once and enabled
again. The setting values of the peak current limiter and the RMS current limiter are restored
to the factory default settings corresponding to the rated power which is determined by the
number of the power units to be energized.
For a polyphase system, the number of power units on which the energization is enabled must
be same on all phases.
If a failure occurs in a power unit for some reason, you can disable the energization for that
unit to restart using this product with the remaining power units. For details, see
8.1.3
.
-----------------------------------------------------------------------------------------------------------------------------
Summary of Contents for KP3000S
Page 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Page 4: ......
Page 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Page 22: ......
Page 42: ......
Page 78: ......
Page 210: ......
Page 220: ......
Page 252: ......
Page 286: ......
Page 288: ......
Page 289: ......