8. Troubleshooting
PROGRAMMABLE AC/DC POWER SOURCE
228
Table 8-3 Actions When a Failure is Suspected (Continued)
Category Symptom
Possible
Cause Necessary
Actions
Sequence/
Simulation-
related
problem
The Sequence
cannot be
started.
The output is off.
Turn on the output, then start the
sequence.
The specified
Step Time is
exceeded.
The Stop Phase is
enabled.
When the stop phase setting is
active, the execution waits for the
Step Time that was set pass, and
keeps the output setting until it
reaches the Stop Phase that was
set, and then transitions to the
next step. As the result, the actual
step time is longer than the set
Step Time. To move to the next
step immediately after the Step
Time, disable the Stop Phase.
4.2
Problem of
polyphase
system
The polyphase
system is not
recognized at
start-up.
The System Cable is not
connected properly.
Check the System Cable
connection for any disconnected
connector, and so on.
Summary of Contents for KP3000S
Page 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Page 4: ......
Page 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Page 22: ......
Page 42: ......
Page 78: ......
Page 210: ......
Page 220: ......
Page 252: ......
Page 286: ......
Page 288: ......
Page 289: ......