2.5 Output and System Cable Connection
KP3000S
15
2.
Connect the output terminal to the load with a cable. Be sure to tighten the screws firmly. If you
want to ground the output terminal at one point only, ground the Lo terminal. The Hi terminal
should not be grounded. If the load has a ground terminal, connect it to the chassis terminal of
the output terminal of this product.
The output terminal that can be grounded is the Lo terminals. Do not ground the Hi terminal.
Hi
Lo
OUTPUT
3.
Attach the resin-molded terminal cover and the output cable holder. Direct the folded part of the
resin-molded terminal cover to the upper side of the product.
OUTPUT
Hi
Lo
Hi
Lo
OUTPUT
Hi
Lo
Do not use this product when the resin-molded terminal cover is removed. Otherwise, an electric
shock might occur.
About outlet (Optional)
The output terminals, the maximum voltage, the maximum current, and available output range are
listed in Table 2-7.
Each outlet can provide up to 15 A of current. If a current exceeding 15 A flows, the circuit breaker
may operate to cut the output. When the circuit breaker operates, the button is pushed out forward.
Pushing in this button resets the breaker, and power can be provided from the outlet.
The outlet is dedicated to AC output. It can be used in the AC or ACDC mode. In the settings below,
the outlet is separated from the output by the internal relay of this product. However, only the Hi
CAUTION
WARNING
Summary of Contents for KP3000S
Page 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Page 4: ......
Page 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Page 22: ......
Page 42: ......
Page 78: ......
Page 210: ......
Page 220: ......
Page 252: ......
Page 286: ......
Page 288: ......
Page 289: ......