3.4 Using the Continuous Function
KP3000S
43
2.
+
Switching the signal source
Press the SHIFT key to enter the shift state (the SHIFT LED illuminates). When you press the 8
key of the numeric keypad during the shift state, the signal source is switched in the following
order: INT, VCA, SYNC, EXT, ADD, INT. Some signal sources may be skipped and cannot be
selected depending on the AC/DC mode.
3.4.2 Setting the Output Range
You can select the 100 V range or 200 V range. Table 3-10 shows the setting range for each range.
--------
Notes
------------------------------------------------------------------------------------------------------------
You cannot switch the output range in the output on state.
-----------------------------------------------------------------------------------------------------------------------------
Table 3-10 The Setting Range per Output Range
Setting Item
Setting Range
100 V range
200 V range
Unit
DC voltage
220.0 to +220.0
440.0 to +440.0
V
AC
voltage
Phase Voltage
SIN, CLP
0.0 to 155.0
0.0 to 310.0
Vrms
ARB
0.0 to 440.0
0.0 to 880.0
Vp-p
Line
voltage
1P3W
SIN
0.0 to 310.0
0.0 to 620.0
Vrms
3P4W
SIN
0.0 to 268.4
0.0 to 536.8
Vrms
External Input Gain
0.0 to 220.0
0.0 to 440.0
Times
Peak current limiter (positive)
Refer to
10.13
Peak current limiter (negative)
RMS current limiter
Voltage Setting Limit
Refer to
10.14
Summary of Contents for KP3000S
Page 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Page 4: ......
Page 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Page 22: ......
Page 42: ......
Page 78: ......
Page 210: ......
Page 220: ......
Page 252: ......
Page 286: ......
Page 288: ......
Page 289: ......