4.1 Using Limiter, Setting Limiter
KP3000S
65
2.
Set the value of RMS current limiter in [Io] item.
3.
Set the [Output OFF] item as [Enable] or [Disable]. When setting to [Enable], also set the time
from the start of limiter operation to the output off.
4.
Close the window.
4.1.3 Using Voltage Setting Range Limit
For the continuous output function, when the signal source is INT, SYNC, or ADD, the range of the
output voltage setting value to the internal signal source can be limited. Even if trying to set a
voltage that exceeds the limit, the setting value is restricted to the limiting value. This can prevent
mis-setting when you do not want to set values outside the range.
As for the voltage setting range limiting values, each value is kept independently for the following
settings for 100 V and 200 V ranges respectively: SIN/CLP waveform in AC mode, ARB waveform
in AC mode, ACDC mode, and DC mode.
In case of polyphase output, the setting of the voltage setting range limit is common to all phases,
and kept as the effective value of the phase voltage in this product. When the line voltage setting
(effective value setting) is selected in balanced mode, it is converted into the effective value setting
of the phase voltage according to the following formula and kept in this product.
Summary of Contents for KP3000S
Page 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Page 4: ......
Page 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Page 22: ......
Page 42: ......
Page 78: ......
Page 210: ......
Page 220: ......
Page 252: ......
Page 286: ......
Page 288: ......
Page 289: ......