WF1945B
3-5
3.2 Input and output connectors
Waveform output (FUNCTION OUT)
50
Ω
FUNCTION OUT
±
42 Vpeak
OUTPUT AMP
50
Ω
20dB
ATT
Maximum output voltage : 20 Vp-p/open, 10 Vp-p/50
Ω
load
Output impedance :
50
Ω
, unbalanced
Load impedance:
More than 45
Ω
Output off status :
Open when output off (can be modified for 50
Ω
at output off. Consult
company.)
Ground :
Connected to signal ground (floating from chassis)
Avoid shorting the output or applying an external signal. The unit can be damaged.
・
Output limiting
If the following voltages are exceeded by the amplitude, DC offset, external add or external AM settings,
the OVER lamp flashes and the output is clipped.
10 V range: Approx. 11 Vp/open
1 V range: Approx. 1.1 Vp/open
・
Output connection note
The Function Out impedance is 50
Ω
. By using coaxial cable with 50
Ω
characteristic impedance for
connection to other equipment, amplitude accuracy at high frequency can be improved and waveform
disturbance reduced. In addition, performance deterioration up to maximum frequency can be
prevented by connecting to a terminal having 50
Ω
input impedance or terminating the input at 50
Ω
.
・
Setting and output voltages
The setting voltage display and actual output voltage (load terminal voltage) differ according to the load
resistance.
“5.4 Other settings (
■
LOAD function (equalize setting and output values))”, cf.
! CAUTION
Summary of Contents for WF1945B
Page 2: ......
Page 3: ...DA00012505 002 WF1945B MULTIFUNCTION SYNTHESIZER Instruction Manual...
Page 4: ......
Page 8: ......
Page 20: ......
Page 30: ......
Page 62: ......
Page 100: ...4 2 Sweep 4 38 WF1945B Sweep value and Z MARKER SYNC X DRIVE outputs is approx 100 to 125 s...
Page 101: ...4 2 Sweep WF1945B 4 39...
Page 128: ......
Page 158: ......
Page 182: ......
Page 184: ......
Page 186: ......
Page 187: ......