Internal Accessories
16
TemBreak
PRO
B_BE-UM-001-EN
– V1.1.0
Shunt Trip
A shunt (normally de-energized) can be installed to trip the MCCB by applying voltage to the shunt coil.
Part Number
Rated voltage
Connection type
AC (V)
DC (V)
T2SH00A10TA
110
─
Terminal
T2SH00A20TA
230…240
─
Terminal
T2SH00A40TA
400…415
─
Terminal
T2SH00D01TA
─
12 Terminal
T2SH00D02TA
*
24 Terminal
T2SH00D04TA
─
48 Terminal
T2SH00D10TA
─
110 Terminal
T2SH00D20TA
─
230 Terminal
* Whilst not a rated voltage, T2SH00D02TA will operate at 24V ac
Rated voltage
AC (V)
DC (V)
100
…
120
200
…
240
380
…
450
12
24
48
100
…
120
200
…
240
Excitation Current (mA)
14.0
14.0
6.5
30.0
30.0
30.0
11.0
11.0
Under Voltage Trips
A UVT (normally energized) can be installed to trip the MCCB removing voltage from the UVT coil.
Part Number
Rated voltage
Compatible MCCB
Connection
Type
Notes
AC (V)
DC (V)
T2UV00A10NTA
110
─
B 250 / 400
Terminal
Instantaneous
T2UV00A20NTA
200…240
─
B 250 / 400
Terminal
Instantaneous
T2UV00A40NTA
380…450
─
B 250 / 400
Terminal
Instantaneous
T2UV00D02NTA
─
24
B 250 / 400
Terminal
Instantaneous
T2UV00D04NTA
─
48
B 250 / 400
Terminal
Instantaneous
T2UV00D10NTA
─
110
B 250 / 400
Terminal
Instantaneous
T2UV00D20NTA
─
230
B 250 / 400
Terminal
Instantaneous
T2UV00A10DS
110
─
B 250 / 400
Terminal
Time Delay 500ms
T2UV00A24DS
230…240
─
B 250 / 400
Terminal
Time Delay 500ms
T2UV00A40DS
440..450
─
B 250 / 400
Terminal
Time Delay 500ms
T2UV00D02DS
─
24
B 250 / 400
Terminal
Time Delay 500ms
T2UV00D10DS
─
110
B 250 / 400
Terminal
Time Delay 500ms
T2UV00D24DS
─
230
B 250 / 400
Terminal
Time Delay 500ms
T2UV80A10NTA
110
─
B 800 / 1000 / 1250 / 1600
Terminal
Instantaneous
T2UV80A20NTA
200…240
─
B 800 / 1000 / 1250 / 1600
Terminal
Instantaneous
T2UV80A40NTA
380…450
─
B 800 / 1000 / 1250 / 1600
Terminal
Instantaneous
T2UV80D02NTA
─
24
B 800 / 1000 / 1250 / 1600
Terminal
Instantaneous
T2UV80D04NTA
─
48
B 800 / 1000 / 1250 / 1600
Terminal
Instantaneous
T2UV80D10NTA
─
110
B 800 / 1000 / 1250 / 1600
Terminal
Instantaneous
T2UV80D20NTA
─
230
B 800 / 1000 / 1250 / 1600
Terminal
Instantaneous
T2UV80A10DS
110
─
B 800 / 1000 / 1250 / 1600
Terminal
Time Delay 500ms
T2UV80A24DS
230…240
─
B 800 / 1000 / 1250 / 1600
Terminal
Time Delay 500ms
T2UV80A40DS
440…450
─
B 800 / 1000 / 1250 / 1600
Terminal
Time Delay 500ms
T2UV80D02DS
─
24
B 800 / 1000 / 1250 / 1600
Terminal
Time Delay 500ms
T2UV80D10DS
─
110
B 800 / 1000 / 1250 / 1600
Terminal
Time Delay 500ms
T2UV80D24DS
─
230
B 800 / 1000 / 1250 / 1600
Terminal
Time Delay 500ms
Rated Voltage
Power supply capacity (VA)
Excitation current (mA)
AC (V)
DC (V)
100
…
110
115
…
120
200
…
220
230
…
240
380
…
415
440
…
450
24
100
…
120
200
…
240
B 250 / 400
1.4
1.4
2.8
2.8
2.3
2.3
23
10
10
B 800 / 1000 / 1250 / 1600
1.5
1.6
2.4
2.9
2.1
2.3
29
13
11
Summary of Contents for TemBreak PRO
Page 45: ...45 TemBreak PRO B_BE UM 001 EN V1 1 0 Annex A Dimensions B250P ...
Page 46: ...Annex A Dimensions B250 46 TemBreak PRO B_BE UM 001 EN V1 1 0 ...
Page 47: ...Annex A Dimensions 47 TemBreak PRO B_BE UM 001 EN V1 1 0 B400P R ...
Page 48: ...Annex A Dimensions B400P R 48 TemBreak PRO B_BE UM 001 EN V1 1 0 ...
Page 49: ...Annex A Dimensions 49 TemBreak PRO B_BE UM 001 EN V1 1 0 B800N H G ...
Page 50: ...Annex A Dimensions B800N H G 50 TemBreak PRO B_BE UM 001 EN V1 1 0 ...
Page 51: ...Annex A Dimensions 51 TemBreak PRO B_BE UM 001 EN V1 1 0 B800P R ...
Page 52: ...Annex A Dimensions B800P R 52 TemBreak PRO B_BE UM 001 EN V1 1 0 ...
Page 53: ...Annex A Dimensions 53 TemBreak PRO B_BE UM 001 EN V1 1 0 B1000N H ...
Page 54: ...Annex A Dimensions B1000N H 54 TemBreak PRO B_BE UM 001 EN V1 1 0 ...
Page 55: ...Annex A Dimensions 55 TemBreak PRO B_BE UM 001 EN V1 1 0 B1250N H HL ...
Page 56: ...Annex A Dimensions B1250N H HL 56 TemBreak PRO B_BE UM 001 EN V1 1 0 ...
Page 57: ...Annex A Dimensions 57 TemBreak PRO B_BE UM 001 EN V1 1 0 B1600N HL ...
Page 58: ...Annex A Dimensions B1600N HL 58 TemBreak PRO B_BE UM 001 EN V1 1 0 ...
Page 89: ...89 TemBreak PRO B_BE UM 001 EN V1 1 0 Annex C I2t Let Through Curves B250P ...
Page 90: ...Annex C I2t Let Through Curves 90 TemBreak PRO B_BE UM 001 EN V1 1 0 B400P R ...
Page 91: ...Annex C I2t Let Through Curves 91 TemBreak PRO B_BE UM 001 EN V1 1 0 B800N H G ...
Page 92: ...Annex C I2t Let Through Curves 92 TemBreak PRO B_BE UM 001 EN V1 1 0 B800P R ...
Page 93: ...Annex C I2t Let Through Curves 93 TemBreak PRO B_BE UM 001 EN V1 1 0 B1000N H ...
Page 94: ...Annex C I2t Let Through Curves 94 TemBreak PRO B_BE UM 001 EN V1 1 0 B1250N H HL ...
Page 95: ...Annex C I2t Let Through Curves 95 TemBreak PRO B_BE UM 001 EN V1 1 0 B1600N HL ...
Page 96: ...96 TemBreak PRO B_BE UM 001 EN V1 1 0 Annex D Peak Let through Curves B250P ...
Page 97: ...Annex D Peak Let through Curves 97 TemBreak PRO B_BE UM 001 EN V1 1 0 B400P R ...
Page 98: ...Annex D Peak Let through Curves 98 TemBreak PRO B_BE UM 001 EN V1 1 0 B800N H G ...
Page 99: ...Annex D Peak Let through Curves 99 TemBreak PRO B_BE UM 001 EN V1 1 0 B800P R ...
Page 100: ...Annex D Peak Let through Curves 100 TemBreak PRO B_BE UM 001 EN V1 1 0 B1000N H ...
Page 101: ...Annex D Peak Let through Curves 101 TemBreak PRO B_BE UM 001 EN V1 1 0 B1250N H HL ...