11
machine’s operation electrical voltage, please refer to the
Chapter 9 “electrical scheme” to undertake the necessary
adjustment on the terminator.
Connect the machine to the electrical
system which should be equipped with
fuse. Perfect grounding should meet
local national regulation. If
necessary, you should equip the
equipment with the electric leakage
protection device to secure the safety
running of the equipment. If the tire
changer without power supply plug, it is
necessary for the user to install one,
the min. electrical current of which
should be 16A and meet the relative
regulation and the electrical voltage of
the machine.
4.4Operation test
When step down the pedal
(
Fig4-17 K
),
the turntable will
rotate clockwise. When rise up the pedal
(
Fig4-17 K
)
,
the
turntable will rotate counterclockwise.
If the rotation direction of the turntable is
different from the direction described in 4.4,
change the wires at the 3-phase terminal.
Step down the pedal H, column U tilt back and once
rise up the pedal, the column will back to its work
position;
Step down the pedal I, 4 pieces of clamping jaw will
open and once rise up the pedal, they will close;
Step down the pedal J, bead breaker blade will go
to the work position and once rise up the pedal, it
will return to its original position;
When fix button at Y position, the tool arm U and
the horizontal arm C will be locked;
When fix button at Z position, the tool arm U and
the horizontal arm C will be released;
Note:When the tire mounted is heavier than 25Kg,
please select the lifting device model SR68 or the
other lifting device. But it is prohibited to lift
by the human force.
Fig 4-16
Fig 4-17
Summary of Contents for TC-1300
Page 1: ...3456789 C61CN...