Page 21
3.4 *1: Save Setup
The NHRC-10 Repeater Controller has 5 “saved configuration setups” that allow the
repeater operator to save five presets of all 80 of the control operator switches.
The default setup is #0 which is loaded when the controller is powered up.
3.4.1 Save configuration setup
*1<n>
where:
<n>
specifies the setup number to save. Valid range is 0 to 4.
After a valid command is received, the controller will respond “OK.”
The other setups can be loaded by using the load saved setup command:
See Section 5.13 for information about the Load Saved Setup command.
Example:
To save the current controller state (all 10 control operator switch groups)
as state #1, send the following command with the controller unlocked: "*11". The
controller will say "OK" if the command is accepted.