4.7 Group 6 Switches: Digital Output Port Configuration
Group 6 contains switches which configure the NHRC-10’s optional 8-output digital
output board.
Group 6 Switches:
Switch Name Description
0
Enable Pulsed Digital
Output 1
When enabled (1), will cause digital output 1 to
be automatically turned off ½ second after it is
turned on, producing a ½ second pulse on the
output.
1
Enable Pulsed Digital
Output 2
When enabled (1), will cause digital output 2 to
be automatically turned off ½ second after it is
turned on, producing a ½ second pulse on the
output.
2
Enable Pulsed Digital
Output 3
When enabled (1), will cause digital output 3 to
be automatically turned off ½ second after it is
turned on, producing a ½ second pulse on the
output.
3
Enable Pulsed Digital
Output 4
When enabled (1), will cause digital output 4 to
be automatically turned off ½ second after it is
turned on, producing a ½ second pulse on the
output.
4
Enable Pulsed Digital
Output 5-8
When enabled (1), will cause each of digital
output 5 through 8 to be automatically turned
off ½ second after it is turned on, producing a ½
second pulse on the output.
5
Set Digital Outputs
“One-Of” Mode
When enabled (1), will set the digital outputs
into a “one-of” mode. In this mode, turning on
any output will first turn off all other outputs,
producing a mode where only one output can be
on at a time. (Hence, the term “one-of”, since
only one of eight outputs can be on at any time.)
6
Reserved
Reserved for NHRC
7
Reserved
Reserved for NHRC