Providing Adequate Clearance
As shown below, the PXIe-1090 module and power supply intake vents are on the right side of
the chassis. The module and power supply exhaust vents are on the left side of the chassis.
Figure 6. PXIe-1090 Cooling Air Flow
1
2
4
3
1. Module Exhaust
2. Power Supply Exhaust
3. Power Supply Intake
4. Module Intake
You must maintain adequate clearance between the chassis and surrounding equipment, heat
generating devices, and air flow blockages to ensure proper cooling. Minimum cooling
clearances are shown in the following figure. For rack mount applications, adequate forced air
ventilation is required. For benchtop or rack mount applications, additional cooling clearances
may be required for optimal air flow and reduced hot air recirculation to the air inlet fans.