background image

Safety Guidelines

Caution

 

You can impair the protection provided by the NI-7935R if you use it in a

manner not described in this document.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements
and limits provide reasonable protection against harmful interference when the product is
operated in the intended operational electromagnetic environment.

This product is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral device or test object,
or if the product is used in residential or commercial areas. To minimize interference with
radio and television reception and prevent unacceptable performance degradation, install and
use this product in strict accordance with the instructions in the product documentation.

Furthermore, any changes or modifications to the product not expressly approved by National
Instruments could void your authority to operate it under your local regulatory rules.

Caution

 

To ensure the specified EMC performance, operate this product only with

shielded cables and accessories. The DC power input cables and optical SFP+ cables
may be unshielded.

Caution

 

To ensure the specified EMC performance, you must use an isolated cable

with the SFP+ ports.

Caution

 

To ensure the specified EMC performance, the length of any cable

connected to the TRIG ports and REF CLK ports must be no longer than 3 m (10 ft).
The length of copper cables connected to the SFP+ ports must be no longer than 3 m
(10 ft). The length of cables connected to the USB device ports or host ports must be
no longer than 30 m (100 ft). The lengths of Ethernet cables and optical SFP+ cables
are not limited.

Caution

 

The USB device port is intended only for use in device configuration,

application deployment, debug, and maintenance.

Verifying the System Requirements

To use the NI-7935R, your system must meet certain requirements. For more information
about minimum system requirements, recommended system, and supported application
development environments (ADEs), refer to the readme, which is available on the software
media or online at 

ni.com/updates

.

4

  | 

ni.com

  | 

NI-7935R Getting Started Guide

Summary of Contents for 7935R

Page 1: ...bout the device specifications refer to the NI 7935R Specifications at ni com manuals Contents FlexRIO Documentation 2 Safety Guidelines 4 Electromagnetic Compatibility Guidelines 4 Verifying the System Requirements 4 What You Need to Get Started 5 Unpacking the Kit 5 Preparing the Environment 6 Wiring Power to the NI 7935R 6 Powering on the NI 7935R 7 STATUS LED 7 ...

Page 2: ...n Locations and Descriptions Document Location Description Getting started guide for your controller for FlexRIO Available from the Start menu and at ni com manuals Contains installation instructions for your FlexRIO system Specifications document for your controller for FlexRIO Available from the Start menu and at ni com manuals Contains specifications for your controller for FlexRIO Getting star...

Page 3: ...ions and adapter module component level IP CLIP FlexRIO Adapter Module Development Kit User Manual Available from the Start menu at Start All Programs National Instruments NI FlexRIO NI FlexRIO Adapter Module Development Kit Documentation Contains information about how to create custom adapter modules for use with FlexRIO FPGA modules LabVIEW Examples Available in NI Example Finder In LabVIEW clic...

Page 4: ...nal Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories The DC power input cables and optical SFP cables may be unshielded Caution To ensure the specified EMC performance you must use an isolated cable with the SFP ports Caution To ensure the specified EM...

Page 5: ...IO adapter module or custom adapter module optional A number 2 Phillips screwdriver A number 1 Phillips screwdriver A small flat blade screwdriver Straight through shielded Ethernet cable if connecting to a network or crossover shielded Ethernet cable if connecting directly to a PC Unpacking the Kit Caution To prevent electrostatic discharge ESD from damaging the device ground yourself using a gro...

Page 6: ...fore returning it to service Wiring Power to the NI 7935R The NI 7935R requires a 9 V to 30 V external power supply that meets the specifications in the NI 7935R Specifications The NI 7935R filters and regulates the supplied power and provides power for the I O modules Note You can latch the power plug to the NI 7935R using two screws tightened to 0 20 to 0 25 N m 1 8 to 2 2 lb in of torque The ma...

Page 7: ... embedded stand alone LabVIEW Real Time application each time you boot the controller STATUS LED The STATUS LED is off during normal operation The NI 7935R indicates specific error conditions by flashing the STATUS LED a certain number of times every few seconds as shown in the following table LED State Indication 2 flashes every few seconds There is no software installed which is the out of box s...

Page 8: ...ntact National Instruments Off Normal operation Connecting the NI 7935R to the Host Computer Complete the following steps to connect the NI 7935R to the host computer using the USB device port 1 Power on the host computer 2 Connect the NI 7935R to the host computer using the USB A to B cable Note Alternatively you can use the RJ 45 Ethernet port to connect the NI 7935R to the host computer The dev...

Page 9: ... getting started guide for your adapter module for more information about your adapter module including programming information Configuring the System in Measurement Automation Explorer MAX After connecting the NI 7935R to the host computer complete the following steps to configure the system for the first time in MAX 1 Launch MAX on the host computer 2 Expand Remote Systems in the MAX configurati...

Page 10: ...eld 3 Click the Security Configuration icon 4 Click Login 5 In the Login dialog box enter the username admin and leave the password field blank 6 Click OK 7 Click Change Password 8 Enter and re enter a new password 9 Click OK 10 Click Save 11 Click OK to confirm you are changing the password Caution NI cannot recover lost system passwords If you forget the password you must contact NI and reformat...

Page 11: ... connected to the host select Existing target or device Select the NI 7935R under Real Time FlexRIO and click OK b If the hardware is not connected to the host select New target or device Select the NI 7935R under Real Time FlexRIO and click OK 4 Right click the target and select New FPGA Target The FPGA target appears in the project under the Real Time target Adding a FlexRIO Adapter Module to th...

Page 12: ... Time Eclipse Edition tutorial Removing the Adapter Module Complete the following steps to remove an adapter module from the NI 7935R 1 Disconnect all cables to the adapter module 2 Power off the NI 7935R 2 3 Unscrew the adapter module 4 Remove the adapter module Troubleshooting the NI 7935R Related Information Connecting the NI 7935R to the Host Computer on page 8 Why Can t the NI 7935R Communica...

Page 13: ...ng them off You may also need to add an exception for MAX In Windows 7 select Start Control Panel System and Security Windows Firewall Allow a program through Windows Firewall Click Allow another program select Measurement Automation click Add then click OK Ensure that UDP port 44525 is open to communication on the host computer If you are using an intelligent switch on the network ensure that it ...

Page 14: ...FlexRIO adapter module connector 11 Port 0 Port 1 SFP connectors Related Information For more information about the NI 7935R front panel connectors buttons and LEDs refer to the FlexRIO Help LED Indicators The following figure shows the NI 7935R LEDs in more detail Figure 4 NI 7935R LEDs RT User LED Power LED Status LED FPGA User LED 14 ni com NI 7935R Getting Started Guide ...

Page 15: ...ondary Side Bank 1 PCB Primary Side GND GPIO_CC_14_n GPIO_CC_14 GND GPIO_15_n GPIO_15 GND GPIO_16_n GPIO_16 GND GPIO_17_n GPIO_17 GND GPIO_18_n GPIO_18 GND GPIO_19_n GPIO_19 GND GPIO_20_n GPIO_20 GND GPIO_21_n GPIO_21 GND GPIO_22_n GPIO_22 GND GPIO_23_n GPIO_23 GND GPIO_58_n GPIO_58 GND GPIO_59_n GPIO_59 GND GPIO_CC_60_n GPIO_CC_60 GND GPIO_61_n GPIO_61 GND GPIO_62_n GPIO_62 GND GPIO_63_n GPIO_63 ...

Page 16: ...rotection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has ...

Page 17: ... application development environment ADE appropriate for your application Services ni com services Updates ni com updates Support ni com support EXPLORE LEARN CREATE DISCOVER FlexRIO ni com flexrio Getting Started with LabVIEW LabVIEW FPGA Module Help FlexRIO Help NI 7935R Specifications LabVIEW Real Time Module Help FlexRIO Support FlexRIO Help FlexRIO Examples NI 7931 7932 7935 User Manual NI 79...

Page 18: ...d party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS U S Governme...