Pollution Degree (IEC 60664)
2
Maximum altitude
5,000 m
Indoor use only.
Shock and Vibration
To meet these specifications, you must panel mount the CompactRIO system and affix ferrules
to the ends of the terminal lines.
Operating vibration
Random (IEC 60068-2-64)
5 g
rms
, 10 Hz to 500 Hz
Sinusoidal (IEC 60068-2-6)
5 g, 10 Hz to 500 Hz
Operating shock (IEC 60068-2-27)
30 g, 11 ms half sine; 50 g, 3 ms half sine;
18 shocks at 6 orientations
Hazardous Locations
U.S. (UL)
Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, AEx nA IIC T4
Canada (C-UL)
Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, Ex nA IIC T4
Europe (ATEX) and International (IECEx)
Ex nA IIC T4 Gc
Safety and Hazardous Locations Standards
This product is designed to meet the requirements of the following electrical equipment safety
standards for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
•
EN 60079-0:2012, EN 60079-15:2010
•
IEC 60079-0: Ed 6, IEC 60079-15; Ed 4
•
UL 60079-0; Ed 5, UL 60079-15; Ed 3
•
CSA 60079-0:2011, CSA 60079-15:2012
Note
For UL and other safety certifications, refer to the product label or the
14
|
ni.com
|
NI cRIO-9101/9102/9103/9104