NI SCXI-1379 Installation Instructions
8
ni.com
Column Expansion
Figure 4 shows how to expand the columns of a 4x32 matrix using a matrix
expansion cable. The matrix expansion cable connects rows to expand the
columns. To expand the columns of a matrix, complete the following steps:
1.
Connect one end of the matrix expansion cable to one of the ROW
CONNECTION CABLE terminals in one of the SCXI-1379 terminal
blocks.
2.
Connect the other end of the matrix expansion cable to one of the ROW
CONNECTION CABLE TERMINALS in another SCXI-1379.
3.
Connect the two SCXI-1379 terminal blocks to the front connectors of
the two SCXI-1130 modules.
4.
Tighten the top and bottom chassis screws on the back of the terminal
block rear panels to hold them securely in place.
Figure 4.
Column Expansion with the SCXI-1379
1
SCXI-1379
2
Matrix Expansion Cable
3
ROW CONNECTION CABLE Terminals
4
32
4
32
4
64
3
2
1
Module 1
Matrix
Expansion
Cable
Module 2