ANOMALY
POSSIBLE CAUSE
INTERVENTION
the compressor will
not start
-
power failure
-
check that there is voltage in the plug
-
temperature setting on probe is too high
-
set the temperature probe to a lower temperature
-
faulty temperature probe
-
check electrical continuity on the probe or replace the probe
-
the over-load protection of the compressor is
faulty
-
replace it
-
the starting relay is faulty
-
replace it
-
the starting capacitor is faulty
-
replace it
-
the compressor is faulty
-
replace it
ZDWHUFRROHULQ(1(5*<6$9,1*PRGH
H[LW(QHUJ\6DYLQJPRGH
the water is cold but
the appliance is ope-
rating excessively or
non-stop
-
little ventilation
-
place the appliance away from the wall
-
the condenser is dirty or covered
-
clean the condenser or free it of its obstacles
-
the thermostat is on maximum cold position
-
adjust it
-
the room temperature is higher than 32°C
-
it is normal that the appliance works at a continuously high room tempe-
rature
the compressor works
continuously, but the
water is not cold
-
gas leak from the cooling system
-
contact a specialised technician (refrigerationist)
-
the compressor is faulty
-
replace the compressor
COOLING SYSTEM
too much noise co-
ming from the applian-
ce, but it is working
normally
-
the machine is not levelled
-
level the appliance using the adjustable feet
- a few pipes are touching some parts inside the
appliance, thus causing it to vibrate
-
adjust the position of the pipes, making sure they do not touch any other
parts
cold water comes out
slowly or not at all
-
low pressure of the inlet water
-
take steps to increase the pressure (autoclave)
-
faulty solenoid valve
-
replace it
FORJJHGZDWHU¿OWHU
-
replace it
)DXOW\ WHPSHUDWXUH SUREH RU HOHFWURQLF FRQWURO
board, causing the ice bank to freeze
-
let the ice melt and raise the temperature. If the result is unsatisfactory
replace the temperature probe or the electronic board
CARBONATING SYSTEM
the carbonated water
LVQRWYHU\¿]]\RUQRW
at all
-
the pressure of the gas in the CO2 reducer is set
to less than 3 bars
-
increase up to 3.5 – 4 bars
-
CO2 cylinder empty
-
replace it
-
the temperature of the outlet water is high
-
set the probe to a lower temperature
-
air bubbles inside the carbonator
-
clean out the carbonator
only gas comes out of
the carbonated water
outlet
-
the level probes are dirty
-
control and replace
-
the pump turns continuously
QRZDWHULVHQWHULQJRUWKHZDWHU¿OWHULVEORFNHG
-
the pump turns continuously, inlet water is pre-
sent
WKHSLSH¿WWLQJLQWRWKHFDUERQDWRULVREVWUXFWHGGLVDVVHPEOHDQGFOHDQ
-
the pump is blocked or the pump-motor is not
working
-
check it and replace it
-
the level controller is faulty
-
control and replace
-
the pump safety device has intervened (no wa-
ter)
-
check that there is pressure in the network
disconnect and reconnect the machine from the electrical network to re-
set it
continuous dripping
from the outlets
-
dirty solenoid valve
-
disassmeble the solenoid valve and clean it
the still water comes
out carbonated
-
there is a shortage of inlet water
-
disassemble and clean or replace