General
With AXC 50 a ground water pump can be connected
to the heat pump if the software controlled output (AUX
output) is used for something else.
This connection enables the use of ground water as heat
source. The ground water is pumped up to an intermedi-
ate heat exchanger. An intermediate heat exchanger is
used to protect the heat pump's exchanger from dirt and
freezing. The water is released into a buried filtration unit
or a drilled well.
The ground water pump runs at the same time as the
brine pump.
Outline diagram
Explanation
External additional heat
EB1
Accessory card (AXC 50)
AA5
Expansion vessel, closed
CM5
External electrical additional heat
EB1
Safety valve, heating medium side
FL10
Shut-off valve, heating medium side
QM42 - QM43
Trim valve
RN11
Heat pump system (Master)
EB100
Temperature sensor, outdoor
BT1
Temperature sensor, hot water charging
BT6
Temperature sensor, heating medium flow,
External
BT25
Temperature sensor, heating medium return,
External
BT71
Heat pump, F1345
EB100
Cooling module A
EP14
Cooling module B
EP15
Safety valve, collector side
FL11 - FL12
Safety valve, heating medium side
FL13 - FL14
Particle filter
HQ12 - HQ15
Shut-off valve, brine side
QM50 - QM53
Shut-off valve, heating medium side
QM54 - QM57
Reversing valve, heating/hot water
QN10
Non-return valve
RM10 - RM13
Collector, brine side, ground water
EP12
Accessory card (AXC 50)
AA5
Heat exchanger, groundwater
EP4
Circulation pump, groundwater
GP3
Particle filter
HQ40
Miscel-
laneous
Manometer, brine side
BP6
Accumulator tank with hot water coil
CP10, CP11
Buffer vessel, UKV
CP20
Expansion vessel, closed, brine side
CM3
Safety valve, brine
FL3
Circulation pump, heating medium external
GP10
Circulation pump, heating medium external
GP18
Venting valve, brine side
QM21
Shut off valve, brine flow
QM33
Shut off valve, brine return
QM34
Non-return valve
RM21
Trim valve
RN60 - RN63
Connection, filling brine
XL27 - XL28
Designations in component locations according to
standard IEC 81346-1 and 81346-2.
Outline diagram F1345 with AXC 50 and ground water pump
-EB100-BT71
-CM3
P
-BP6
-QM21 -FL3
-XL28
-XL27
-QM33
-QM34
-EB100-BT1
-EB100-BT25
-EP4
-HQ40
-AA5
-EP12
-EP12
-GP3
-HQ15
-HQ14
-RM12
-RM13
-QM54
-FL12
-QM55
-QM56
-QM57
-FL13
-HQ13
-RM11
-HQ12
-RM10
-QM50
-QM51
-FL10
-QM52
-QM53
-FL11
-EB100
-EP15
-EP14
-EB100
-EB100
-BT6
-CP10
-RN63
-RN62
-CP11
-RN60
-RN61
-EB100-QN10
-CM5
-FL10
-QM42
-QM43 -RN11
-EB1-AA5
-EB1
-EB1
-RM21
-GP18
-CP20
-GP10
25
Chapter 7 |
Groundwater pump
AXC 50
7 Groundwater pump
Summary of Contents for AXC 50
Page 1: ...Installer manual LEK AXC 50 Accessories IHB GB 1222 1 231158...
Page 2: ......
Page 10: ...Electrical circuit diagram AXC 50 Chapter 3 Shunt controlled additional heat 8...
Page 15: ...Electrical circuit diagram 13 Chapter 4 Step controlled additional heat AXC 50...
Page 21: ...Electrical circuit diagram 19 Chapter 5 Extra climate system AXC 50...
Page 26: ...Electrical circuit diagram AXC 50 Chapter 6 Hot water comfort 24...
Page 29: ...Electrical circuit diagram 27 Chapter 7 Groundwater pump AXC 50...
Page 34: ...Electrical circuit diagram AXC 50 Chapter 8 Passive cooling 4 pipe 32...
Page 40: ...Electrical circuit diagram AXC 50 Chapter 9 Passive cooling 2 pipe 38...
Page 46: ...Electrical circuit diagram AXC 50 Chapter 10 Passive active cooling 2 pipe 44...
Page 47: ......
Page 48: ...NIBE AB Sweden Hannabadsv gen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu 231158...