background image

GB

16

!

The minimum distance in front of 
the stove opening to combustible 
parts of the building or interior 
decoration must be at least 1,2 m.

The dimension diagrams only 
show the minimum permitted 
installation distances for the 
stove. When connecting to a steel 
flue, also note the safety distance 
requirements of the flue. The 
safety distance between an un-
insulated flue and a combustible 
part of the building should be at 
least 450 mm.

Installation distances 

WHEN INSTALLING TURNTABLE (OPTION) 

the follow-

ing installation distances do not apply. 
See the separate turntable installation instructions.

A =  height from floor to chimney 

connection upwards

B =  height from floor to c/c chimney 

connection rear

C = height from floor to air inlet
D = height from floor to lower edge 

of hatch

A separate glass hearth 
plate (accessory) 
increases the connection 
height to the chimney by 
10 mm.

Permitted area for 

combustible parts 

of the building

*    If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing  
 

glass hearth plate this is 10 mm.

**  To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.

INSTALLATION AGAINST COMBUSTIBLE WALLS

INSTALLATION AGAINST FIREWALLS

1290

580

2100*

D 367

92

219

Combustible roof

140

110

B 1078*

A 1205*

C 389

40

515

Air inlet Ø67

Ø150

848

685

335

100

Combustible wall

650

780

636

285

50

650

Fire-retardant wall
of brick or concrete

1100

520

192

50

227**

900

Fire-retardant wall
of brick or concrete

800

507

570

570

242

100

Combustible wall

C620T / C620TG Style

Summary of Contents for Contura C620T

Page 1: ...C620T C620TG contura eu...

Page 2: ...nces 16 Distanze di sicurrezza 25 Installasjonsavstand 10 Installationsafstand 19 Installatieafstand 28 Prestandadeklaration 5 D claration des performance 14 Suoritustasoilmoitus 23 Leistungsdeklarati...

Page 3: ...e becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable ma...

Page 4: ...rom floor to lower edge of hatch A separate glass hearth plate accessory increases the connection height to the chimney by 10 mm Permitted area for combustible parts of the building If the stove is pl...

Page 5: ...safety Pass Fire classification A1 Minimum distance to flammable materials Rear 100 mm Side 507 mm Ceiling 810 mm Front 1200 mm Floor 0 mm Corner 100 mm Fire hazard due to burning fuel falling out Pa...

Page 6: ...he insert needs to be put down to be moved loose components should be removed Removal of the hearth cladding is described at the end of these installation instructions 1 Grille 2 Grate disc 3 Base cov...

Page 7: ...rnstein Bakmontering til murt skorstein Raccordement par l arri re une chemin e de ma onnerie Rear connection to a masonry chimney Tilslutning bagud til muret skorsten Liit nt taaksep in muurattuun sa...

Page 8: ...rdement la chemin e par le haut Top connection to the chimney The hot air grille must be installed before chimney top connection Toptilslutning til skorsten Varmluftristen skal v re monteret f r skors...

Page 9: ...HK HK 40 mm 1 2 HK 40 mm HK 40 mm 3 4 33 SE DE NO FR GB DK FI IT NL Tilluft Zuluft Tilluft Arriv e d air Supply Forbr ndingsluft Tuloilma Alimentazione dell aria Toevoerlucht...

Page 10: ...3 4 1 2 34...

Page 11: ...6 5 7 8 35...

Page 12: ...9 10 36...

Page 13: ...11A 1 11A 2 37...

Page 14: ...11B 1 11B 2 38...

Page 15: ...11B 3 12 39...

Page 16: ...oor can be secured in the open position using the locking lever on the left side of the stove Door in open position for cleaning service Sp rring af l gen ved reng ring service L gen kan sp rres i ben...

Page 17: ...ildstedsbekledningen Vermikulitt Voici comment d monter l habillage du foyer Vermiculite How to remove the hearth surround Vermiculite S dan afmonterer du ovnbekl dningen Vermiculite N in irrotat tuli...

Page 18: ...4 6 5 3 42...

Page 19: ......

Page 20: ...811460 IAV SE EX C620T Style 1 2021 10 29 NIBE AB Box 134 285 23 Markaryd Sweden contura eu...

Reviews: